Infrared insight for mission-critical environments

See risk before
it becomes failure.

Engineering-led, in-person thermal surveys and clear technical reports for data centres, electrical infrastructure and critical facilities across Europe.

Non-contactinspection
Operationalasset scanning
Actionabletechnical reports
LIVE THERMAL ANALYSIS SCANNING
PDU–04 / PANEL Bε 0.95 SPOT 0172.4°C
01 Thermal anomaly detected
02 Evidence captured
European project experience
PARISMADRIDFRANKFURTMILANAMSTERDAM

01 — INFORMATION

Temperature tells a story.
We turn it into a decision.

Infrared thermography converts emitted infrared energy into a visual temperature map. It allows trained personnel to examine equipment quickly and without physical contact, revealing abnormal heat patterns that ordinary visual checks can miss.

For data centres, where power continuity and cooling performance are fundamental, thermal surveys add a valuable layer of condition monitoring across electrical and mechanical systems.

01

Electrical systems

FLIR and Fluke-assisted inspection of switchgear, UPS systems, ATS and STS systems, generators, panels, terminations and distribution assets.

02

Cooling & airflow

Data-centre cooling and airflow assessment, including hot and cold aisle performance, CRAC and CRAH systems, fan motors, pumps and pipework.

03

Evidence & reporting

Reports containing the measured evidence and engineering context clients need when considering maintenance, investigation or operational changes.

02 — THE SCAN

01

Establish
the baseline.

Capture assets under representative operating load and document the environmental conditions that affect interpretation.

02

Reveal the
invisible.

Compare thermal patterns across phases, components and similar assets to identify meaningful temperature differences.

03

Prioritise
the response.

Translate observations into an engineering report that helps the client investigate, plan maintenance and retain evidence.

ASSET / LV-SWGR-03SCAN 00%
ΔT +27.9°C

03 — WHY IT MATTERS

Small thermal differences can signal
large operational consequences.

01

Reduce unplanned downtime

Find developing electrical, mechanical or cooling issues before they have the opportunity to disrupt critical operations.

02

Plan maintenance intelligently

Use measured evidence to support investigation, prioritisation and targeted maintenance rather than relying on guesswork alone.

03

Create a trendable record

Repeatable scan routes and consistent reports help teams compare asset condition over time and verify post-repair results.

04

Strengthen documentation

Clear image pairs and temperature data provide a practical audit trail for facilities teams, clients and relevant stakeholders.

04 — EXAMPLE WORK

From scan to
actionable evidence.

Illustrative examples of the observations and reporting format an in-person thermal survey can provide.

PANEL A / PHASE L267.8°C
Priority review

Abnormal phase heating

A comparative temperature pattern that may justify further electrical investigation under an approved safe system of work.

Discuss a similar survey
RPP 02 / TERMINATION59.1°C
Monitor / investigate

Localised connection hotspot

A concentrated thermal signature at a termination, recorded with context, temperatures and a clear equipment reference.

Discuss a similar survey
COLD AISLE / RACK 1424.6°C
Performance insight

Airflow distribution pattern

A wider-area thermal view used to help identify temperature distribution and potential hot-air recirculation.

Discuss a similar survey

Demonstration imagery only — not evidence from a completed client survey.

THERMOGRAPHIC SURVEY
CLIENTCritical Facility — Demo
ASSETLV Switchboard 03
MAX68.7°C
REFERENCE40.8°C
ΔT+27.9°C
OBSERVATION 01Priority technical review

05 — THE DELIVERABLE

A report built for the people who need to act.

Each finding is structured to make the evidence easy to understand, locate and pass to the appropriate engineering or maintenance team.

  • 01Asset and location references
  • 02Visible and thermographic image pair
  • 03Measured temperatures and relevant comparison
  • 04Observation, context and suggested priority
  • 05Clear digital report for client records

06 — QUALIFICATIONS & EQUIPMENT

Engineering judgement,
supported by specialist tools.

Our attended inspection approach combines infrared thermography, power-quality analysis and practical engineering experience across critical power and data-centre infrastructure.

Fluke 1777 Power Quality Analyzer
POWER QUALITY ANALYSIS

Fluke 1777

High-speed three-phase power-quality analysis for capturing transients, harmonics, dips, swells and electrical-system performance.

FLIR E96 thermal imaging camera
THERMAL IMAGING

FLIR E96

High-resolution 640 × 480 thermal imaging for detailed inspection of electrical, mechanical and critical-infrastructure assets.

Elspec G4500 monitoring system
ON-SITE POWER QUALITY

Elspec G4500

Attended power-quality recording with continuous waveform capture and detailed event analysis during agreed on-site investigations.

01

Thermography-led inspection

Thermal findings are captured in person and interpreted in an engineering context, with clear asset references and measured evidence.

02

Critical power systems

Experience across UPS, ATS and STS systems, generator sets, switchgear, distribution equipment and supporting infrastructure.

03

Attended site surveys

Services are delivered through planned in-person scans using professional FLIR, Fluke and Elspec equipment.

04

On-site connectivity

Industrial router connectivity can support secure instrument communication and data transfer during attended investigations where required.

05

Verified leadership credentials

Public professional credentials include Engineering Council UK Incorporated Engineer registration, MIET membership, BCIA Advanced Certificate Building Controls 01–06 and PE AQPE Spain recognition.

06

Critical-infrastructure delivery

Leadership experience covers electrical commissioning, power quality, thermography and data-centre critical infrastructure across Europe.

Iulian Catalin Tabacu, CEO of CATAB&CO Ltd
CEO / INCORPORATED ENGINEERIULIAN CATALIN TABACU

07 — LEADERSHIP

“A useful survey does more than show a hot spot. It gives the client clear evidence, technical context and a practical next step.”

CATAB&CO Ltd combines data-centre engineering experience with structured infrared inspection and concise reporting. The aim is straightforward: provide decision-makers with dependable information before a developing issue becomes an operational problem.

Critical infrastructureEuropean project experienceTechnical reporting

START A CONVERSATION

Make the invisible
actionable.

Tell us about your facility, asset scope and reporting requirements. Emergency and out-of-hours attendance may be arranged, subject to engineer availability and an enhanced call-out rate.

Contact CATAB&CO Ltd